Walmart+Electric+DryersCette fonctionnalité n’est pas disponible pour le moment. Veuillez réessayer ultérieurement. The photo shows a metal strap installed it goes from the white wire down the side of the terminal block, and is screwed to the dryer frame. If this strap is not accessible (and it commonly isn’t) buy a one particular-foot piece of #ten green wire, strip an inch of insulation from every single end, and set up that wire involving the connector the white wire applied to go to and the connector on the frame exactly where the green wire utilised to go.

The good news is that dryer cords are readily obtainable and fairly low-cost, and it isn’t really hard to switch them. A screwdriver and a pair of pliers will do the job, although some nut drivers would be nice. As extended as there is a wire from the frame to the center terminal, exactly where the white wire was, it is sufficient. There will be some kind of connector holding the dryer cable to the wall of the dryer so that it does not pull out. The most common type is a clamp with two screws on the outdoors that can be tightened to squeeze the wire into location. Loosen these screws so that the wire can slide out of the dryer.

Lots of (most) dryers have a white wire on the center post that is not from the cord, but rather goes deep into the dryer. You did correct in just leaving it there. There will also be the ground wire that goes each there and to the frame of the dryer, plus the center wire of the new cord. Two, most likely 3 and maybe even a lot more wires on that center terminal. Verify that the other two connections are snug. If you have a voltmeter, each and every of the outside two terminals should really show 120V to ground or neutral, or 240V amongst the two.

Get rid of each wire from the screw or stud holding it, making sure to save all nuts or screws. Take away the cover plate from the wire terminal block, exposing the wires inside. Note where every color of wire terminates. Usually, you will see a row of three terminal screws, with the red and black wires connected to the two outdoors screws, the white wire connected to the center screw, and the green wire connected to the frame of the dryer.

Commence by unplugging the dryer. There is higher voltage inside (240 volts) that can give you a pretty nasty shock, even kill you. Make certain there is no chance of this, by unplugging the dryer just before proceeding any additional. I feel I just answered this, but…no. Neither the ground strap is to go to the center terminal it is illegal to ground the neutral wire there, and that is what you have done. Instead, eliminate the ground strap from that terminal, remove the green wire from there, and put the green wire to where the other finish of the ground strap attaches to the frame of the dryer.

The photo shows a metal strap installed it goes from the white wire down the side of the terminal block, and is screwed to the dryer frame. If this strap is not out there (and it generally is not) obtain a 1-foot piece of #ten green wire, strip an inch of insulation from every single finish, and install that wire amongst the connector the white wire utilized to go to and the connector on the frame exactly where the green wire used to go.Walmart+Electric+Dryers

As soon as the 4-wire cord is removed, it is time to install the new 3-wire cord and plug. Function the wire by way of the connector, but do not tighten it yet. The red and black wires go to the outer two terminals (in the photo the dryer wires are black and blue) and the white wire goes to the terminal in the center of the terminal block. Though the red and black wires are interchangeable, the white wire is not make sure it goes to the center terminal, exactly where the old white wire was.

Many (most) dryers have a white wire on the center post that is not from the cord, but rather goes deep into the dryer. You did suitable in just leaving it there. There will also be the ground wire that goes both there and to the frame of the dryer, plus the center wire of the new cord. Two, possibly three and possibly even more wires on that center terminal. Check that the other two connections are snug. If you have a voltmeter, every of the outside two terminals must show 120V to ground or neutral, or 240V among the two.

Is this a secure and acceptable practice / layout? Unit operates terrific – but would like to know if this is going to be a concern. My apologies. That is a photo of a variety outlet, not a dryer outlet. At least it inspired you to ask, even though, so perhaps it’s not all undesirable. Acquire a variety cord and you must be fine. What the three-wire connection will appear like, such as a metal ground strap (circled) between the dryer frame and the white wire. You can use a #10 wire instead of a strap.

Leave a Reply